Code | Description | Model | Tech. Note | Manual | Stock | |
DGMA01A3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 24 Vac - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
|||
DGMA01A4 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 24 Vac - Visualiz: direct 20,0 A |
DGM D4 |
![]() |
|||
DGMA03A3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 115 Vac - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
|||
DGMA03A4 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 115 Vac - Visualiz: direct 20,0 A |
DGM D4 |
![]() |
|||
DGMA06A3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 230 Vac - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
|||
DGMA06A4 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 230 Vac - Visualiz: direct 20,0 A |
DGM D4 |
![]() |
|||
DGMA07A3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 240 Vac - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
|||
DGMA07A4 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 240 Vac - Visualiz: direct 20,0 A |
DGM D4 |
![]() |
|||
DGMA0HA3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 20...150 Vdc/48 Vac - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
|||
DGMA0HA4 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 20...150 Vdc/48 Vac - Visualiz: direct 20,0 A |
DGM D4 |
![]() |
|||
DGMA0LA3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 150...250 Vdc - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
|||
DGMA0LA4 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 150...250 Vdc - Visualiz: direct 20,0 A |
DGM D4 |
![]() |
|||
DGMA21A3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 24 Vac - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
![]() |
||
DGMA23A3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 115 Vac - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
![]() |
||
DGMA26A3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 230 Vac - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
![]() |
||
DGMA27A3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 240 Vac - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
![]() |
||
DGMA2HA3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 20...150 Vdc/48 Vac - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
![]() |
||
DGMA2LA3 |
RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 150...250 Vdc - Visualiz: direct 9,99 A |
DGM D4 |
![]() |
![]() |
||
DGMD01D1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 24 Vac - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMD03D1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 115 Vac - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMD06D1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 230 Vac - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMD07D1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 240 Vac - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMD0HD1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMD0LD1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 150...250 Vdc - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMD21D1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 24 Vac - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMD23D1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 115 Vac - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMD26D1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 230 Vac - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMD27D1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 240 Vac - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMD2HD1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMD2LD1 |
RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 150...250 Vdc - Visualiz: 100 V…250 kV (43 selectable ranges) |
DGM D4 |
![]() |
![]() |
Description | Model | Tech. Note | Manual | Stock | ||
DGMG01C1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG01C2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG03C1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG03C2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG06C1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG06C2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG07C1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG07C2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG0HC1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG0HC2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG0LC1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG0LC2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG21C1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG21C2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG23C1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG23C2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG26C1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG26C2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG27C1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG27C2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG2HC1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG2HC2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG2LC1 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMG2LC2 |
Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V |
DGM D4 |
![]() |
![]() |
||
DGMM01L4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMM03L4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMM06L4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMM07L4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMM0HL4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMM0LL4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |
Description | Model | Tech. Note | Manual | Stock | ||
DGMM21L4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMM23L4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMM26L4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMM27L4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMM2HL4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |
||
DGMM2LL4 |
Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges) |
DGM D4 |
![]() |
![]() |